Menu

The ULS checks – EC – EN 1993 Steel Check ULS are not available in the Steel menu.

It might occur that the ULS checks – EC – EN 1993 Steel Check ULS are not available in the steel menu while calculating a steel structure. Therefore the user will not be able to perform an overall, a section or a stability check in order to optimize the structure.  

This issue indicates an incorrect selection of the National Code in the Project data. It might be possible that the user accidently selected the Eurocode – European pre-Standard instead of the actual Eurocode. This can be resolved by executing following procedure: 

  1. Open the “Project data” and select [...] next to the National Code “EC – ENV”;


     

  2. Select “Add” in the tab “Codes in project”;


     

  3. Select the correct national code in the tab “Available national codes”, in this case “EC – EN” and confirm with “OK”;


     

  4. When the window “Codes in project” is closed, a warning message concerning the modification of applied code is shown which needs to be confirmed with “OK”;


     

  5. Select the “National annex” which needs to be applied in the project and close the project data.


     

Reference number: 
ESA1506
Software: 
FAQ Category: 
Steel
Access Type: 
Free User
Tags: